Mechanically operated valves, push-button valves, hand lever valves, roller lever valves

Over 30,000 high-quality products for pneumatic control and drive technology and drilling

Made in Germany

Made in Germany: AIRTEC offers you a wide selection in the areas of pneumatic control and drive technology and drilling as well as innovative customised solutions, which we develop for you and with you and bring to series production readiness. You can rely on our certified quality and technical expertise.

 

Mechanically and manually operated valves require neither an electrical nor a pneumatic control signal. The switching force is applied directly at the point of actuation: by an operator moving a hand lever or pressing a button, or by a moving machine part that depresses a plunger or runs over a roller lever. This makes them the first choice wherever no power supply is available, where a machine has to be enabled manually, or where end-position sensing is to be done purely pneumatically, without electronic sensors and without going through the PLC.

The AIRTEC portfolio comprises mechanically operated directional control valves in 3/2-, 4/2-, 4/3-, 5/2- and 5/3-way configurations with port sizes from M5 to G1/2, with mechanical and manual actuation options as well as panel-mount operators.

 

Actuation Options at a Glance

Mechanical Actuation

  • Plunger: for direct actuation by an approaching machine part; compact and mechanically robust.

  • Roller lever: for cams or machine parts that run over the roller. The valve switches in both directions of travel and then returns to its rest position.

  • Roller lever with idle return: switches in one direction of travel only and trips idly in the opposite direction. Required wherever the return stroke must not trigger an additional signal.

Manual Actuation

  • Hand lever, momentary or detented: the classic hand lever valve for switching on, reversing and shutting off.

  • Rotary and toggle levers for operator stations requiring a defined switching position.

  • Push button and push-pull button: push-button valves for short signals and start/stop functions.

  • Foot pedal: foot-operated valves for manual workstations where both hands remain on the workpiece.

Panel-Mount Operators

For integration into control desks and enclosure doors, push buttons, rotary switches, toggle switches, key-operated buttons and lockable stop buttons are available. This allows purely pneumatic control panels to be built without running a single electrical cable.

 

Direct-Acting Rather Than Pilot-Operated

With very few exceptions, AIRTEC’s mechanically operated valves are direct-acting: the actuating force acts directly on the switching element, and no pilot circuit is required. The valve therefore switches without a minimum pilot pressure and without consuming any pilot air. The actuating force required depends on the valve principle: with poppet valves, it increases with nominal size and operating pressure, whereas with pressure-balanced spool valves, it is largely independent of pressure. The specific values for each series are given in the data sheet.

The ST-18 series is the exception: this push-button valve is pilot-operated so that it can be actuated with very little force; a light tap is sufficient. In return, it requires a minimum pressure and consumes a small but continuous amount of pilot air during operation.

 

Valve Functions and Configurations

3/2-Way Valves

Three ports, two switching positions, normally closed (NC). When actuated, the outlet is pressurised; when released, it is exhausted. Typical applications: single-acting cylinders, enabling and shut-off functions, signal generation in pneumatic control systems.

Normally open (NO) operation is achieved not through dedicated versions but through the port connections: many valves allow flow in both directions and can be operated as NO by connecting the compressed air supply to port 3 instead of port 1. This is only permitted for valves whose circuit symbol shows this (flow arrows in both directions).

4/2- and 4/3-Way Valves

Functionally, these correspond to the 5/2- and 5/3-way valves. The only difference lies in the exhaust routing: both exhaust paths are combined into a single common port, which is used by one side or the other depending on the switching position.

5/2-Way Valves

Five ports, two switching positions. These valves control double-acting actuators by alternately pressurising both sides of the piston, making them the standard choice for linear and rotary actuators and handling tasks. Available as a monostable version with spring return and as a bistable, detented version that holds its switching position without continuous actuation.

5/3-Way Valves

The same port configuration as the 5/2-way valve, but with a defined centre position. As a 5/3-way hand lever valve, it is the typical solution for set-up and manual operation: the actuator can be moved in both directions and stopped in an intermediate position. For the mechanically operated series, closed centre and exhausted centre versions are available.

 

Poppet or Spool Valve: Which Principle for Which Application?

Poppet valves seal against a valve seat by means of a soft elastomer seal. They are leak-free, tolerant of contamination and suitable for higher operating pressures. At AIRTEC, series E and series T work on this principle.

Spool valves use an axially sliding spool. They enable significantly higher flow rates with moderate switching forces that are largely independent of pressure, and their design makes it easier to implement multiple valve functions and centre positions. Series H and the 84 series 84-4H, 84-4F, 84-HPV and 84-4HV work on this principle.

Series Overview

Series Actuation Port Nominal size Valve function Temperature ATEX
E Plunger, roller lever, idle return, hand lever M5-G1/8 2-4 mm 3/2, 5/2 -10...+70 °C optional
T Push button, push-pull button, mushroom-head button M5-G1/8 2-4 mm 3/2, 5/2 -10...+70 °C optional
H Hand lever, momentary (HF) or detented (HR) G1/8-G1/2 6-14 mm 3/2, 5/2, 5/3 -10...+70 °C optional
84-4H Hand lever, momentary (HF) or detented (HR) G1/8-G1/2 4.5-6.5 mm 5/2, 5/3 0...+60 °C –
84-4F Foot pedal, momentary or detented G1/4 9 mm 5/2 0...+60 °C –
84-HPV Toggle lever, detented G1/8-G1/4 4-6 mm 5/2 0...+60 °C –
84-4HV Rotary lever, detented G1/8-G1/4 5 mm 4/2, 4/3 0...+70 °C –

Applications for Mechanically and Manually Operated Valves

  • Jigs, fixtures and clamping: end-position sensing without electronic sensors, control of clamping units

  • Conveyor systems: pallet stops and indexing control via roller lever and plunger valves

  • Manual workstations and presses: foot-operated and push-button valves for triggering when both hands are occupied

  • Machine tools: hand lever valves for set-up and manual operation and for shutting off and exhausting

  • Hazardous areas: purely pneumatic operation without an electrical ignition source

 

FAQs

Here are the frequently asked questions.

When is a mechanically operated valve the right choice?

Whenever no control signal is available: without a power supply, in set-up and manual operation, for shutting off and exhausting, and for end-position sensing without electronic sensors. If the machine is electrically controlled anyway, a solenoid valve is the better choice.

What is the difference between mechanically and manually operated valves?

Mechanically operated means that a machine part switches the valve, for example via a plunger or roller lever. Manually operated means that an operator switches it via a hand lever, push button or foot pedal. This distinction is not defined by any standard.

 

Are mechanically operated 3/2-way valves available as NO versions?

AIRTEC does not offer dedicated NO versions. However, many series allow flow in both directions and can be operated as NO by connecting the compressed air supply to port 3 instead of port 1.

Can mechanically operated valves be used in hazardous areas?

Yes. Selected series are available as ATEX versions, and a large proportion are approved for use in hazardous areas, as they have no electrical ignition source of their own; mechanical ignition sources are assessed depending on the installation conditions. A prerequisite is a ported exhaust with a threaded connection so that the exhaust air can be routed out of the zone. Small plunger and push-button valves with an open exhaust hole do not meet this requirement.

What is the service life of mechanically operated valves?

The service life corresponds to that of the other AIRTEC series, as the valve internals are largely identical. In practice, the number of switching cycles is rarely the limiting factor here. Spare parts are available for wearing parts such as the lever.

What compressed air quality is required?

Compressed air to ISO 8573-1:2010, Class 7:2:4 (filtered, oil-free, dried and free from aggressive constituents). However, the pressure dew point must be at least 10 °C below the lowest expected ambient temperature. The same requirements apply as for the pneumatically and electrically operated series.

Contact us

Do you have a special requirement or an idea?
Let's find a solution together!

We look forward to your enquiry.

Phone: +49 6173 95620
E-Mail: info@airtec.de

Go to contact form